Chamberlain CSL24UL Installation Manual.Csl24ul manual

Looking for:

Csl24ul manual 













































   

 

TABLE OF CONTENTS.Csl24ul manual



 

Elite series comercial dc vehicular slide gate operator. Hide thumbs. Table Of Contents. Quick Links. Table of Contents. Access installation and technical support. Take a photo of the.

Send it in by texting the. Previous Page. Next Page. Vehicular gate systems provide convenience and security. Gate systems 9. The gate operator is only one line-of-sight of the gate.

Activation of the reset control shall not cause component. For a copy, contact ASTM directly at or www. Conduit and Concrete Pad Safety Trench and install conduit.

Before trenching, contact underground Entrapment protection devices are required to protect against any entrapment or utility locating companies. Conduit must be UL approved for low safety conditions encountered in your gate application.

Standard Installation 1. The gate operator should be installed near the front roller of the gate. Lay out the concrete pad. Install the electrical conduit. The gate operator should be installed near the front roller of the gate or near the back of the gate in the OPEN position. The space between the gate and the output sprocket must be a minimum of 4 inches Manually open the gate and line up the front bracket so the chain will be level with the idler pulley and parallel to the ground.

Weld the front bracket in this position. NOTE: This installation will require two extra idler pulleys. Make sure all exposed pinch points are guarded. Refer to Gate Construction Information on page 1. Move the back pulley to the bottom hole in the operator. Entrapment protection devices MUST be installed to protect anyone Locate entrapment protection devices to protect between moving gate who may come near a moving gate.

Refer to the specific entrapment protection device manual for more information. These entrapment protection device inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors.

The ground wire must be a single, whole piece of wire. Never splice two wires for the ground wire. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length. Step 7 Connect Batteries 7AH battery The batteries are charged in the circuit by the integrated transformer.

The batteries are for battery backup or solar installation. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. Wired dual gate applications will have a longer battery standby time than wireless applications.

Wireless setup To activate the wireless feature: 1. The operator cover consists of two pieces: a rear cover and a front cover. The front cover can easily be removed to access the electrical box.

To access the reset switch slide the access door up. When programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed.

Your specific site requirements may be different. Always setup the operator system to the site requirements, including all necessary entrapment protection devices. The firmware version will show after the operator type, example "1. Release the handle on the operator arm to allow the gate to be opened and closed manually. On a dual gate application the handle must be released on both operators. To resume normal function tighten the handle by pushing it down.

Reset Switch Normal operation The reset switch is located on the front of the operator and serves several Relay activates prior to motor activation and during motor run. Relay is off when motor is off. Function of relay contact activation determined by switch settings. Test the gate operator monthly. The gate MUST reverse on contact with an object or reverse when an object activates the noncontact ANY maintenance to the operator or in the area near the operator sensors.

The operator alarm will beep 3 times with a command if the battery is low. Batteries do not perform well in extremely cold temperatures. For best performance, the batteries should be replaced every 3 years. Use only LiftMaster part NP for replacement batteries.

To View the Codes The codes will show on the diagnostic display. If a code is not saved it will briefly appear on the display as it occurs, then disappear. If an obstruction did NOT Wireless edge triggered occur, check inputs and wiring.

No power to control board a. Check AC and battery power run and diagnostic b. Open fuse b. Check fuses display not on. If on battery power only, low or dead c. Open control active a. Check all Open inputs for an active input will not close with b. Vehicle loop detector active b.

Check all vehicle detector inputs for an active detector transmitter or c. Defective main board to expansionboard a. Check main board to expansion board wiring. If required, replace wire function not wiring cable. Incorrect input wiring to expansion board b. Check wiring to all inputs on expansion board. Solar panel recommendations are based upon the average solar radiation and the temperature effects on batteries in the given zones as shown on the A maximum of six 10W solar panels Model SP10W12V.

Wire the solar panels Proceed to the Dual Gate section if applicable or proceed to the Adjustment section. Refer to the Programming section. Initial Limits and Force Adjustment Adjust the limits For dual gate applications the limits will have to be set for each If the limits have already been set the operator will exit the limit setting Single-button to 4-button, visor or key chain.

Posts not Model LM included. Print page 1 Print document 56 pages. Rename the bookmark. Delete bookmark? Cancel Delete. Delete from my manuals? Sign In OR. Don't have an account? Sign up! Restore password. Upload manual. Upload from disk. Upload from URL.

 

Csl24ul manual.LiftMaster® CSL24UL Slide Gate Installation Manual



 

This model is for use on vehicular passage gates ONLY and not intended for use on pedestrian passage gates. Take a photo of the camera icon including the points. Send it in by texting the photo to Safety Symbol and Signal Word Review Usage Class UL Entrapment Protection Requirements Safety Installation Information Gate Construction Information Carton Inventory Operator Specifications Site Preparation Types of Installations Step 1 Determine Location for Operator Step 2 Install the Operator Step 3 Attach the Chain Step 4 Install Entrapment Protection Step 5 Earth Ground Rod Step 6 Power Wiring Step 7 Connect Batteries Step 8 Dual Gate Setup Step 9 Install the Cover Limit and Force Adjustment Obstruction Test Remote Controls Not Provided LiftMaster Internet Gateway not provided Erase All Codes Erase Limits Gate Hold Open Feature Entrapment Protection Devices Gate Operator Setup Examples Control Board Overview Manual Disconnect Reset Switch Operator Alarm Remote Control External Control Devices Miscellaneous Wiring Expansion Board Overview Auxiliary Relay 1 and Wiring Accessories to the Expansion Board Important Safety Instructions Maintenance Chart Drive Train Diagnostic Codes Diagnostic Codes Table Control Board LEDs Troubleshooting Chart Step 6 Solar Panel s Dual Gate Settings Limit Setup With a Remote Control When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of Serious Injury or Death if you do not comply with the warnings that accompany them.

The hazard may come from something mechanical or from electric shock. Read the warnings carefully. Read them carefully. WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm.

For more information go to www. A vehicular gate operator or system intended for use in garages or parking areas associated with a residence of one-to four single families.

A vehicular gate operator or system intended for use in a commercial location or building such as a multi-family housing unit five or more single family units , hotel, garages, retail store, or other buildings accessible by or servicing the general public. A vehicular gate operator or system intended for use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to service the general public.

A vehicular gate operator or system intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. It is the responsibility of the installer to install external monitored entrapment protection devices in each entrapment zone.

Keep the remote control away from children. The gate MUST reverse on contact with an object or reverse when an object activates the noncontact sensors. After adjusting the force or the limit of travel, retest the gate operator.

Have a qualified service person make repairs to gate hardware. Pedestrians MUST use separate entrance. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application.

Improperly designed, installed or maintained systems can create risks for the user as well as the bystander. Gate systems design and installation must reduce public exposure to potential hazards. A gate operator can create high levels of force in its function as a component part of a gate system. Therefore, safety features must be incorporated into every design. Specific safety features include:. Install the gate operator only when:. The operator is appropriate for the construction and the usage class of the gate.

All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet 1. All exposed pinch points are eliminated or guarded, and guarding is supplied for exposed rollers. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.

The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.

Permanently mounted access controls intended for users to activate, must be located at least 6 feet 1. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. Exception: Emergency access controls only accessible by authorized personnel e. Activation of the reset control shall not cause the operator to start. Each placard is to be visible by persons located on the side of the gate on which the placard is installed.

For a gate operator utilizing a non-contact sensor:. See Install Entrapment Protection section. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier. For a gate operator utilizing a contact sensor such as an edge sensor:. One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing edge and post mounted both inside and outside of a vehicular horizontal slide gate.

A hard wired contact sensor shall be located and its wiring arranged so the communication between the sensor and the gate operator is not subject to mechanical damage. A wireless device such as one that transmits radio frequency RF signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction.

   

 

Csl24ul manual.LiftMaster® CSL24U Slide Gate Operator Installation Manual



    WebLiftmaster CSL24UL User Manual Download for 1 COMMERCIAL DC VEHICULAR SLIDE GATE OPERATOR INSTALLATION MANUAL Model CSL24UL THIS PRODUCT IS TO . WebSummary of Contents for Chamberlain CSL24UL. Page 1 COMMERCIAL DC VEHICULAR SLIDE GATE OPERATOR INSTALLATION MANUAL • THIS PRODUCT IS TO BE . WebInstallation Manual for LiftMaster Commercial DC Vehicular Swing Gate Operator Model CSW24UL Download Manual - English Download Manual- SpanishDownload Manual - . WebSummary. CSL24UL Slide Gate Installation Manual Link. Article Locked for Edit. Content. Download Manual - English. Download Manual - French. Download Manual - Spanish. .


Comments